How to Evaluate Pouch Filling Accuracy
Updated
Define test conditions, sample sizes and weight checks for pouch filling. Compare accuracy claims only when product and operating conditions match.
Evaluate pouch filling accuracy from net contents, mean error and individual variation at the intended operating speed. Define the product, pouch, measurement method and acceptance limits before the trial so each result has comparable conditions.
[01]
Define Weight or Volume
First decide what you control: the weight in each pouch or the volume. Don't mix them. A liquid dosed by volume changes weight with density and temperature. A powder dosed by auger can fill a set volume and still weigh differently as it aerates or settles.
Write the target in the unit you will check, such as net product mass in grams. Net mass excludes the pouch and closure. Identify the scale and include the same packaging components in the gross and tare measurements. If your label claims are by weight, test by weight. If you have a volume spec, say how you'll verify it. Measuring volume in a flexible pouch is harder than weighing it.
[02]
Product and Operating Conditions
A result belongs to its conditions. Record these with it:
- product name, batch, temperature, density or bulk density, viscosity or particle size;
- pouch type, size and material;
- machine model, dosing method and setup;
- running speed in pouches per minute;
- feed condition, such as hopper level or tank pressure;
- operator, date and scale.
Speed needs care. Speed with an empty machine isn't output with your product. Accuracy usually changes with speed, so a slow-speed result doesn't carry over to a fast run. Test at the speed you plan to run. Our liquid and paste and powder pages cover how product behavior affects dosing.
[03]
Sampling and Measurement
Plan the sample before the test. Decide how many pouches to check and when in the run to take them. Consecutive pouches show short-term variation. Samples spread across the run help identify drift; record their timing and any change in settings or feed condition.
Use a scale suited to the target weight, and record its resolution. A coarse scale can't show small variation. Weigh the empty pouch or use a tare method. Let the scale settle, and keep drafts and vibration away. Net weight = gross weight − pouch tare. NIST's Weighing and Scales FAQs defines tare as packaging and gross load as packaging plus product.
A simple record sheet looks like this:
| Pouch no. | Time | Gross weight | Pouch tare | Net weight | Target | Difference | Pass / fail | Note |
|---|---|---|---|---|---|---|---|---|
| 1 | ||||||||
| 2 | ||||||||
| 3 | ||||||||
| 4 |
Add a header block for the conditions above and keep the sheet with the trial report.
[04]
Bias and Variation
Two different things hide inside "accuracy". Bias is how far the average net weight sits from the target. Variation, or spread, is how much single pouches differ from each other.
Calculate from the measured net weights:
- Mean net weight = sum of measured net weights / number of sampled pouches.
- Bias = mean net weight − target net weight, using the same unit.
- Range = highest net weight − lowest net weight.
Record standard deviation as well when it is part of the acceptance plan. NIST's Engineering Statistics Handbook, Measures of Scale explains the range and standard deviation as measures of spread.
The fixes differ too. Check the scale, tare and feed conditions before changing the set point to correct a stable mean offset. Investigate individual variation through product condition, feeding and the dosing cycle; shifting the target alone does not reduce that spread.
Calculate both from your records: the mean against the target, and the range or standard deviation for spread. Report them separately.
[05]
Underfill and Overfill
Decide before the trial what happens to pouches outside the limit. Underfill can breach label claims. Overfill gives product away. The two limits aren't always symmetric.
Agree on:
- the lower and upper limits, and whether they apply per pouch or to the average;
- whether out-of-limit pouches are rejected, by a checkweigher or by hand;
- what happens to rejects, and whether product is recovered;
- how many out-of-limit pouches a sample may contain, if any.
Automatic rejection is an inspection item and belongs in the quote scope. See what affects price.
[06]
Agree on Acceptance Criteria
Write the criteria before the trial and sign them off with the supplier. A usable set names:
| Element | What to write down |
|---|---|
| Product and batch | The material used |
| Pouch | Type, size, material |
| Speed | Pouches per minute |
| Sample size and method | How many, when, from where in the run |
| Measurement | Scale, resolution, tare method |
| Limits | Target, lower and upper limits for mean and single pouches |
| Result | How pass and fail are decided |
Extend acceptance testing across the intended material lots, pouch formats and run duration. Our sample testing page works the same way: agree the method first, and the record states product, packaging, configuration, settings and observations.
If you have a trial in mind, send us your target and your own method and we'll go through them with you. The selection guide shows where accuracy fits in the larger brief.
[07]
Frequently Asked Questions
- 01Can I compare accuracy claims from two suppliers?
Only if product, pouch, speed, sample size and method match. Otherwise the numbers describe different tests. Ask each supplier for the conditions, and test both under yours if they differ.
- 02How many pouches should I weigh?
There's no single right number. More pouches give a better estimate of bias and spread, and a longer run shows drift. Agree the number in advance and weigh enough that one odd pouch doesn't decide the outcome.
- 03Do I need a checkweigher?
Specify an inspection and rejection step when the process must separate out-of-limit pouches. A checkweigher can perform that check; the selection depends on the weight range, required throughput and reject handling.
[08]
Common Pitfalls in Accuracy Testing
Some habits make results look better or worse than they are. Weighing only the first pouches misses drift. A coarse scale hides variation. Changing the set point mid-test without a note ruins the record. Testing a clean, free-flowing sample when production material is sticky or lumpy gives a result that won't hold.
Don't mix weight and volume checks either. A pouch that looks full isn't evidence of correct net weight.
Keep records: conditions, raw weights, calculated bias and spread, and any adjustments. If you repeat the test later, the old record is your reference. Share the template with the supplier before the trial so both sides know what's measured.
[Related Pages]
- [Product filling]Liquid Pouch Filling Machines for Your Product and PouchReview liquid and paste pouch filling options by viscosity, fill size and closure type. Share product details to check a suitable configuration.View page →
- [Product filling]Powder Pouch Filling Machines for Premade PouchesCompare powder dosing, dust-control considerations and pouch sealing requirements. Review your powder properties, target weight and pouch sample.View page →
- [Engineering & support]Product and Pouch Sample EvaluationPlan a pouch-filling evaluation with production materials, fill and closure measurements, timed output, acceptance criteria and sample handling.View page →
[Request]
Discuss Trial Acceptance Criteria
Discuss the equipment scope and next steps with the LINEVO team.